Techlogiks loose tube cables are the product of choice as the backbone in Indoor/Outdoor environments. Optical Fibers are placed inside filled buffer tubes containing gel and containing up to 12 optical Fibers. The loose tube design offers reliable transmission performance over a broad temperature range.
Standards Compliance:
Telecordia GR-20, IEC 60794, EIA/TIA, ITU-T, EN187000, RUS1755.900
Applications:
Indoor and Outdoor, Trunk, distribution and feeder cable, Local loop, metro, long-haul and broadband network
Advantages:
High fiber density, Multiple network applications, Reduces cable prep and installation time, Reduces cost, Installation of more fibers in less space
Cable Construction Details |
Parameter |
Dimensions |
Type, Color |
Number of Fiber per tube |
12 |
Color |
Bl |
Or |
Gr |
Br |
Sl |
Wh |
Rd |
Bk |
Yi |
Vi |
Pi |
Nt |
8 |
Color |
Bl |
Or |
Gr |
Br |
Sl |
Wh |
Rd |
Nt |
|
|
|
|
6 |
Color |
Bl |
Or |
Gr |
Br |
Sl |
Nt |
|
|
|
|
|
|
4 |
Color |
Bl |
Or |
Gr |
Nt |
|
|
|
|
|
|
|
|
2 |
Color |
Bl |
Nt |
|
|
|
|
|
|
|
|
|
|
Number of Loose Tubes |
1 |
Color |
Nt |
|
|
|
|
|
|
|
|
|
|
|
Loose Tube ID/OD |
1.7/2.5 ± 0.1
mm |
PBT |
Peripheral Strength Member |
--- |
Glass yarn |
Outer Sheath |
1.8 mm (min.) |
LSOH - Black |
Number of Ripcords |
1 |
Polyester |
Overall Cable Diameter |
7.3 ± 0.5 mm |
|
Cable Weight |
60.0 ± 5
kg/km |
|
Optical Fibre Characteristics |
Fibre Type |
62.5 µm (OM1) |
Attenuation |
at 850 nm |
≤ 3.2 dB/km |
at 1300 nm |
≤ 1.2 dB/km |
Bandwidth |
850 nm |
≥ 200 MHz.km |
1300 nm |
≥ 600 MHz.km |
Core Diameter |
|
62.5 ± 2.5 µm |
Core Cladding Concentricity Error |
|
≤ 1 µm |
Cladding Diameter |
|
125 ± 1 µm |
Cladding Non-circularity |
|
≤ 1 % |
Coating Diameter |
|
250 ± 15 µm |
Cable Mechanical Characteristics |
Tensile Strength |
500 N |
Crush Resistance |
1000 N |
Impact Strength |
5 N.m |
Torsion |
± 360 ⁰ |
Minimum Bend Radius |
Short Term - 20 x D |
Temperature Performance |
Installation |
-20 ⁰C to + 70 ⁰C |
Operation |
-20 ⁰C to + 70 ⁰C |
Storage |
-20 ⁰C to + 70 ⁰C |
ORDERING INFORMATION |
Part Number |
Description |
TL-02F-62-UA |
2 Fiber MM 62.5/125µ Ind/Out Unarmored Jelly Filled Loose Tube FOC LSZH |
TL-04F-62-UA |
4 Fiber MM 62.5/125µ Ind/Out Unarmored Jelly Filled Loose Tube FOC LSZH |
TL-06F-62-UA |
6 Fiber MM 62.5/125µ Ind/Out Unarmored Jelly Filled Loose Tube FOC LSZH |
TL-08F-62-UA |
8 Fiber MM 62.5/125µ Ind/Out Unarmored Jelly Filled Loose Tube FOC LSZH |
TL-12F-62-UA |
12 Fiber MM 62.5/125µ Ind/Out Unarmored Jelly Filled Loose Tube FOC LSZH |